You are here: Home - Line interactive UPS with sine output - ORVALDI LT-1100-3000
series: Line interactive UPS with sine output
ORVALDI LT-1100-3000
Uninterrupted power, refined. ORVALDI LT-1100-3000 sinus tower offers a seamless pure sine wave output for high-end appliances and server-class devices.
PRODUCT FEATURES:
- Pure sine wave output for reliable operation of sensitive devices.
- High output power factor (0.7).
- Programmable power management outlets.
- ECO mode for energy saving.
- Emergency power off (EPO) capability.
- High efficiency in battery mode.
- Boost and buck AVR for voltage stabilization.
- Three-stage intelligent battery charging.
- Multiple communication options: standard RS232 and USB, optional SNMP card.
- 6 IEC320 C13 outlets in LT-1100
- 8 IEC320 C13 outlets in LT-2000/LT-3000
LIST OF APPLICATIONS:
- Household electronics
- Emergency lighting
- Alarm systems
- Telecommunications equipment
- Fiscal devices
- Servers and small networks (passive PFC)
- Central heating pumps
- Fireplace pumps
DOWNLOAD:
"HIGH QUALITY" OPTION:
ORVALDI will, in accordance with the terms and conditions of insurance, replace, repair or compensate ORVALDI products and/or connected devices in the event of damage as a result of an electrical surge. The maximum total amount compensated is 5000Euro (five thousand Euros).
Topology
Line-Interactive system with pure sine wave output ensures stable and clean energy supply, perfect for sensitive electronic equipment.
Display
Features an informative LCD display that shows status and system metrics clearly, enhancing user interaction.
LT1100 Connection Outlets
LT-1100 with 6 IEC320 C13 outlets providing ample connectivity for multiple devices
LT-2000 and LT-3000 Connection Outlets
LT-2000/LT-3000 with 8 IEC320 C13 outlets, providing ample connectivity for multiple devices
Communication ports
Equipped with USB, RS232 and optional SNMP card for versatile connectivity and easy management through various platforms.
Network Control and Monitoring Features
Network Control and Monitoring Features
- Enables control and monitoring of multiple UPS units via LAN and INTERNET.
- User-friendly power analysis chart: event statistics, historical data graph export.
- Real-time dynamic UPS data charts (voltage, frequency, load level, battery level).
- Secure OS shutdown and data loss protection in the event of a power failure.
- Warning notifications via audible alarm, broadcast program, mobile messenger, and email.
- Scheduled UPS on/off, battery test, programmable outlet control, and audible alarm control.
- Password protection and remote access management.
- Supports VMware ESX and ESXi.
- Multilingual support: English, German, French, Spanish, Italian, Portuguese, Polish, Czech, Russian, Ukrainian, Turkish, Chinese.
The UPS is equipped with USB and RS232 ports, as well as an SNMP card slot, allowing for easy management and remote monitoring from a computer, enhancing the safety of connected devices.
ViewPower |
ViewPower Pro |
SNMP Web Manager |
Smart management software to monitor and control multiple UPS via LAN and Internet. | Advanced management software to monitor and control multiple UPSs via LAN, Internet, and SNMP card. | SNMP Web Manager is a SNMP web card manager software. Users can search and operate all SNMP devices in the LAN via this interface. Then, user can double click device to open web server monitoring page. |
AVR
Integrated Boost and Buck AVR provides excellent voltage stabilization, critical for maintaining uninterrupted operations.
Additional Features
Supports ECO mode for energy saving and has programmable power management sockets.
TECHNICAL DATA:
MODEL | ORVALDI LT-1100 sinus | ORVALDI LT-2000 sinus | ORVALDI LT-3000 sinus |
Apparent power / active power | 1100 VA / 770 W | 2000 VA / 140 W | 3000 VA / 2100 W |
INPUT | |||
Permissible voltage range | 162-268 VAC/162-268 VAC/170-280 VAC/177-290 VAC | ||
Frequency range | 50/60 Hz ±5 Hz auto-detection | ||
OUTPUT | |||
Voltage regulation (AC mode) | 208 (-10%/+16%) / 220(-15%/+10%) / 230(-15%/+10%) / 240(-15%/+10%) VAC | ||
Voltage regulation (battery mode) | 208 / 220 / 230 / 240 VAC +/-1.5% (before battery alarm) | ||
Frequency range (battery mode) | 50 Hz / 60 Hz +/- 0.1 Hz | ||
Peak factor | 3:1 | ||
Harmonic distortion | 2% max. @ 100% linear load, 5% max. @ 100% non-linear load (before low battery alarm) | ||
Transient time | Typically 2-6 ms, max. 10 ms | ||
Voltage shape (bat.) | Pure sine wave | ||
Overload capacity (AC mode) | 103%~120% (-5%/+10%) 5 min. | ||
120%~150% (-5%/+10%) 10 s. | |||
>150% (-5%/+10%) 1 s. | |||
Overload capacity (battery mode) | 103%~110% (-5%/+10%) 1 min. | ||
110%~150% (-5%/+10%) 10 s. | |||
>150% (-5%/+10%) 0,5 s. | |||
EFFICIENCY | |||
AC mode | 96% | ||
Buck & Boost mode | 95% | ||
Battery mode | ? 88%, up to 90% at nominal voltage | ||
BATTERY | |||
Type and number of batteries | 12 V/ 7 Ah x 2 | 12 V/ 7 Ah x 4 | 12 V/ 9 Ah x 4 |
Voltage | 27.4 VDC ±1% | 54.8 VDC ±1% | |
Charging time(to 90%) | 4h | ||
PROTECTION | |||
Full protection | Protection against overload, over-discharge and over-charging of the battery | ||
ALARM | |||
Battery mode | Beep every 10 seconds | ||
Low battery level | Beep every 2 seconds | ||
Overload | Beep every second | ||
Battery replacement alarm | Beep every 2 seconds | ||
Error | Continuous beep | ||
PHYSICAL | |||
Dimensions, D x S x W (mm) | 397 x 145 x 220 | 455 x 145 x 220 | |
Net weight (kg) | 11.2 | 18.1 | 19.6 |
ENVIRONMENT | |||
Operating humidity | 0-90% RH @ O - 40°C (non-condensing) | ||
Noise level | Less than 45dB | ||
MANAGEMENT | |||
Smart RS-232/USB | Support for Windows @ 2000/2003/XP/Vista/2008,Windows @ 7, Linux, Unix and MAC (downloadable soft - | ||
Optional SNMP | Power management from SNMP manager and web browser |